Max series Ball Valve |
VR series |
![]() |
Ball valve for flow control. V-ported segment provides maximum versatility in control, and various types of fluid are acceptable. It has an equal percentage inherent flow characteristic, and stem seal structure provides excellent durability. | |||
Connection | J10K flanged V-ported | |||
Material | Stainless | |||
Valve DN | R15 to 80A | |||
Maximum Pressure in MPa | 1.0 | |||
Fluids | Water, Oil, Gas, Steam, Corrosive fluid |
Production Data |
|
||||||
|
![]() |
||||||
|
|
||||||
|
|
||||||
Stem Seal |
R-PTFE + FKM O-ring (ST: FKM O-ring for steam) |
Valve |
H |
H2 |
W |
W2 |
L |
Cv |
|
J10K | |||||||
R15A |
52 |
. |
115 |
. |
108 |
1.3
|
|
15A |
52 |
. |
115 |
. |
108 |
4 |
|
20A |
55 |
. |
115 |
. |
117 |
7.5 |
|
25A |
64 |
. |
145 |
. |
127 |
12 |
|
32A |
70 |
. |
145 |
. |
140 |
20 |
|
40A |
83 |
. |
220 |
. |
165 |
31 |
|
50A |
91 |
. |
220 |
. |
178 |
48 |
|
65A |
118
|
124 |
320
|
157 |
190
|
85
|
|
80A
(-080) |
130
|
150 |
320
|
157 |
203
|
123
|
NOTE: The option ST seat is needed for steam. |
Outside Drawing |
|
![]() İFlow |
![]() |
Inherent flow characteristic | Pressure / Temperature Rating |
![]() |
![]() |
Product Code |
|
MAXVRL-1T |
With manual lever |
MAXVRG-1T |
With handwheel with gear unit |
MAXVR0-1T![]() ![]() ![]() |
Valve only |
|
ex. 20A -> -020 |
|
LM:Limit switch for open/close signal detection (one-point type) |
ST:Seat for abnormal pressure rise prevention |
![]() |
|
|