Pneumatic Actuated Ball Valve
 BR series
TADBR PHOTO Flanged-end valve for a wide range of pressure and temperature. It's designed for high temperature steam by choosing an appropriate seat material. Stem seal structure provides excellent durability.
Connection J10K J20K flanged, Full bore
Material Stainless
Valve DN 15 to 150A
Maximum Pressure in MPa 1.0 / 2.0
Fluids Water, Oil, Gas, Steam, Chemicals,Vacuum TORR

Production
Data

 STANDARD DRDER

4Body

 T SCS13A
 U SCS14A

5Ball

 T SCS13A

 U SCS14A

6Seat

 F G F: F-PTFE  G: R-PTFE

 Stem Seal

 R-PTFE +FKM O-ring (ST for steam)


Valve Type

Actuator

*H

 

L

W Cv

Valve
DN

2
Sizing
code

PND-
PSO-
PSC-
TAD-
TAO-
TAC-
PND
PSO
PSC
TAD
TAO
TAC
J10K J20K PND/
PS*
TAD/
TAO&TAC
J10K J20K

15A

0

03D 04D

040

126 143

163

163

108

140 113/190 110/249 18

20A

0

03D 04D

040

130 146

166

 166

117

152 113/190 110/249 40
2 04D 050 146   204  204 132/ 170/305

25A

0

04D 04D

050

143 143

211

 211

127

165 132/190 170/305 80

32A

0

04D 04W

050

149 149

217

 

140

. 132/279 170/305 145

40A

0

. .

063

. .

209

 209

165

190   204/367 210

50A

0

. .

063

. .

217

 217

178

216   204/367 410

2

. .

080

. .

290

 290   240/435

65A

0

. .

080

. .

272

 281

190

241   240/435 620

80A

0

. .

080

. .

284

 293

203

283   240/435 1100

2

. .

100

. .

315

 324   294/530

100A

0

. .

100

. .

341

 

229

.   294/530 2100
2 . . 125 . . 366     366/688
125A
0
. .
125
. .
384
 
356
.   366/688 3200
150A 0 . . 160 . . 456   394 .   446/838 5000

NOTE:
The option ST seat is needed for steam. In this case, the flow direction is limited.
For foreign matter or R-PTFE seat, high viscous service, please consult for actuator selection.
J20K:can be used used at material SCS13A for valve DN 15A, 20A 32A and 40A.
*H
When using high temp. fluid (over 150°C) , the option for thermal insulation is needed.
Please consult us.

 

Pressure / Temperature Rating

Outside Drawing

Seat material  F:F-PTFE  G:R-PTFE

BR GAIKEI

Valve DN:15A - 20A

BR TEMP

Valve DN:25A - 80A

BR TEMP2

Valve DN:100A - 150A
BR TEMP3


Product Code

BR CODE

 

Actuator

Control action

Actuator

Double-acting
type

PND
TAD

Single-acting
type

Reverse
operation

PSO
TAO

Regular
operation

PSC
TAC

 
Option
LB: LS box for open/close signal detection  (two-point type)
LC: Electric-pneumatic integrated positioner Limit SW
BS: Speed control with by-pass valve PPS(Double-acting)
EP: Electro-pneumatic positioner

 

HOME