| Pneumatic Actuated Ball Valve |
| TR/LR series |
![]() |
Flanged-end 3-way valve for a wide range of pressure and temperature. Stem seal structure provides excellent durability. | |||
| Connection | J10K flanged, Full bore | |||
| Material | Stainless | |||
| Valve DN | 20 to 100A | |||
| Maximum Pressure in MPa | 1.0 | |||
| Fluids | Water, Oil, Gas, Steam, Chemicals | |||
|
Production Data |
|
||
|
|
|
||||||||||
|
|
|
||||||||||
|
|
|
||||||||||
|
Stem Seal |
R-PTFE+FKM O-ring (ST:FKM O-ring for steam) |
||||||||||
|
Valve Type |
Actuator |
H |
L |
W |
Cv |
|||||||
|
Valve |
|
|
PSO- PSC- |
TAO- TAC- |
|
PSC |
TAD TAO TAC |
PND/ PS* |
TAD/ TAO&TAC |
ON/ OFF |
Effected Cv value |
|
| 20A | 0 | 04D | 04D | 050 | 146 | 146 | 204 | 150 | 132/190 | 170/305 | 24 | 10 |
|
25A |
0
|
04D | 04W |
050 |
143 | 143 |
211 |
170 |
132/279 | 170/305 |
40 |
20 |
|
40A |
0
|
. | . |
063 |
. | . |
209 |
200 |
204/367 |
100 |
60 | |
|
50A |
0
|
. | . |
063 |
. | . |
217 |
230 |
204/367 |
170 |
110 | |
|
2
|
. | . |
080
|
. | . |
290
|
240/435 | |||||
|
65A |
0
|
. | . |
080 |
. | . |
271 |
260 |
240/435 |
240 |
150 | |
|
80A |
0
|
. | . |
080 |
. | . |
283 |
280 |
240/435 |
380 |
240 | |
|
2
|
. | . |
100
|
. | . |
314
|
294/530 | |||||
|
100A |
0
|
. | . |
100 |
. | . |
340 |
340 |
294/530 |
680 |
440 | |
| 2 | . | . | 125 | . | . | 365 | 366/688 | |||||
|
For solvent or high viscous service, please consult for actuator selection. |
||
|
Flow Paths (TR:front views, LR:top views) |
Outside Drawing |
|
|
|
|
|
|
Position1 |
||
|
dividing: Flows from C port to A, B port. |
||
|
mixing: Flows from A, B port to C port. |
||
|
Pressure / Temperature Rating |
||
|
Valve DN 20A - 50A |
||
![]() |
||
| Valve DN 65A - 100A | ||
![]() |
||
| Inherent flow characteristic | ||
![]() |
||
|
Product Code |
|
|
|
Actuator |
Control action |
Actuator |
||
|
Double-acting |
TAD |
|||
|
Single-acting |
Reverse |
|
||
|
Regular |
|
|||
| Option | ||||
| LB: | LS box for open/close signal detection (two-point type) | |||
| LC: | Electric-pneumatic integrated positioner Limit SW | |||
| BS: | Speed control with by-pass valve PPS(Double-acting) | |||
| EP: | Electro-pneumatic positioner | |||
|
|
|