| Pneumatic Actuated Butterfly Damper |
| WT series |
![]() |
It's designed for a wide range of temperature. Valve body and disc made by precision processing ensure reduced leakage from valve seat. |
||
| Connection | J5K flanged, Full bore Wafer type | ||
| Material | Stainless | ||
| Valve DN | 40 to 400A | ||
| Maximum Pressure kPa |
20 (2000mmAq) | ||
| Fluids | Gas | ||
|
Production Data |
|
||
|
|
|
||||||||||
|
Disc |
SUS420J2/SUS420J1(Seat:None) |
||||||||||
|
|
|
|
|||||||||
|
Stem Seal |
|
||||||||||
|
Valve Type |
Actuator |
*H |
L |
W |
Cv |
||||
|
Valve |
Sizing code |
|
|
TAD |
TAO |
TAD | TAO TAC |
||
| 40A | 0 | 050 | 050 | 255 | 255 | 40 | 170 | 305 | 85 |
| 50A | 0 | 050 | 050 | 260 | 260 | 40 | 170 | 305 | 145 |
| 65A | 0 | 050 | 050 | 272 | 272 | 40 | 170 | 305 | 290 |
|
80A |
0 |
050 |
050 |
304 |
304 |
50 |
170 | 305 |
450 |
|
100A |
0 |
050 |
050 |
315 |
315 |
50 |
170 | 305 |
780 |
|
125A |
0 |
050 |
050 |
333 |
333 |
50 |
170 | 305 |
1200 |
|
150A |
0 |
050 |
050 |
347 |
347 |
50 |
170 | 305 |
1800 |
| 2 | 063 | 063 | 362 | 362 | 204 | 367 | |||
|
200A |
0 |
050 |
050 |
370 |
370 |
50 |
170 | 305 |
3200 |
| 2 | 063 | 063 | 385 | 385 | 204 | 367 | |||
| 250A | 0 | 063 | 063 | 407 | 407 | 50 | 204 | 367 | 5100 |
| 2 | 080 | 080 | 472 | 472 | 240 | 435 | |||
| 300A | 0 | 063 | 063 | 433 | 438 | 55 | 204 | 367 | 7200 |
| 2 | 080 | 080 | 498 | 498 | 240 | 435 | |||
| 350A | 0 | 080 | 080 | 527 | 527 | 70 | 240 | 435 | 8900 |
| 2 | 100 | 100 | 580 | 580 | 294 | 530 | |||
| 400A | 0 | 080 | 080 | 551 | 551 | 70 | 240 | 435 | 11000 |
| 2 | 100 | 100 | 604 | 604 | 294 | 530 | |||
|
NOTE: |
||
| Pressure / Temperature Rating | ||
![]() |
||
|
Inherent flow characteristic
|
||
![]() |
||
| Outside Drawing | ||
|
||
| Leakage | ||
| Standard type:less than 1% | ||
| (40/50A:less than 2%) | ||
| With seal-ring type :less than 0.1% | ||
| (40A:less than 1% , 50A:less than 0.5%, 65A:less than 0.2%) | ||
|
Product Code |
![]() |
|
Actuator |
Control action |
Actuator |
Option |
|
|
Double-acting |
|
LB: LS box for open/close signal detection |
||
|
Single-acting |
Reverse |
|
LC:Electric-pneumatic integrated positioner Limit SW | |
|
Regular |
|
BS:Speed control with by-pass valve PPS Double-acting) |
||
| EP:Electro-pneumatic positioner | ||||
|
|
|