Electric Actuated Butterfly Valve |
FN/F series |
|
Light weight, low price and economical valve. Various seat and disc materials are available. | |||
Connection | J10K/ J5K(for FN series only) flanged, Wafer type | |||
Material | Various | |||
Valve DN | 50 to 300A | |||
Maximum Pressure in MPa | 1.0 | |||
Fluids | Water, Gas, Oil (EPDM seat is not acceptable), Slurry, Vacuum 1 torr, Sea water (ALBC3) |
Production Data | ![]() ![]() |
||||||||||||||
![]() |
|
||||||||||||||
![]() |
|
||||||||||||||
![]() |
|
||||||||||||||
Stem Seal | Depend on seat material |
Valve Type |
Actuator |
H |
L |
Cv |
||||||||
FN/F |
|
|
|
|
PHX- PHR- |
AE1 |
AD* |
PDX PHX PHR |
FN type |
F type |
||
Valve |
|
|||||||||||
50A |
0 |
300 |
360 |
300 |
300 |
300 |
273 |
332 |
332 |
41 |
41 |
159 |
65A |
0 |
300 |
360 |
300 |
300 |
300 |
290 |
349 |
349 |
44 |
44 |
266 |
80A |
1 |
. |
. |
300 |
300 |
. |
. |
356 |
. |
44 |
44 |
457 |
0 |
600 |
700 |
700 |
700 |
700 |
313 |
356
|
356 | ||||
100A |
0 |
600 |
700 |
700 |
700 |
700 |
346 |
384 |
384 |
51 |
51 |
860 |
125A |
1 |
. |
. |
700 |
700 |
. |
384 |
. |
54 |
54 |
1320 |
|
0 |
02K |
02K |
. |
02K |
02K |
399 |
406 |
406 | ||||
150A |
0 |
02K |
02K |
. |
02K |
02K |
412 |
419 |
419 |
54 |
54 |
2020 |
200A |
1 |
02K |
02K |
. |
02K |
02K |
453 |
460 |
460 |
60 |
64 |
3540 |
0 |
06K |
06K |
. |
06K |
06K |
513 |
501 |
501 | ||||
250A |
0 |
06K |
06K |
. |
06K |
06K |
545 |
533 |
533 |
. |
64 |
5580 |
300A |
1 |
06K |
06K |
. |
06K |
06K |
583 |
571 |
571 |
. |
76 |
8080 |
NOTE: |
Inherent flow characteristic |
Outside Drawing |
|
|
|
|
Seat material and temperature rating |
Seat material |
Temperature rating |
Application |
EPDM |
-20 to 80°C |
for water |
NBR (Nitrile rubber) |
-10 to 60°C |
for oil, air, slurry |
PTFE (Teflon) |
-40 to 80°C |
for acid, alkali, corrosive fluid |
CR (Chloroprene rubber) |
-10 to 90°C |
for weather resistance, chemical resistance |
FKM (Fluorine rubber) |
-5 to 80°C |
for high temp. fluid, chemical resistance |
|
EPDM seat cannot be used for oil. |
The temperature for water must be up to 80°C. Steam cannot be used. |
Sizing code 1 can be used for clean fluid |
Thermal insulation is needed for low temp. fluid below -20°C. Please consult us. |
|
|
|
Actuator |
Power Supply |
High-power |
Note |
Control |
|
||
AC |
|
|
Standard ON-OFF type |
|
1: AC100/110V |
||
|
|
Built-in relay |
|
2: 200/220V |
|||
|
High speed operation |
|
|||||
|
Built-in relay |
PHR- | |||||
DC |
|
DC power supply type |
0: DC24V | ||||
Option | |
L*: | Auxiliary signal limit switch |